MHRA Published New Guidance on Re-Manufacturing of Single-Use Devices

By Elisabethann Wright & Julia Fraser on July 8, 2016
Email this postTweet this postLike this postShare this post on LinkedIn

The UK Medicines and Healthcare products Regulatory Agency (MHRA) has published new guidance permitting re-manufacturing of single-use devices (SUD) under certain conditions.

The MHRA recognised that that re-manufacturing is already widely used in a number of countries and that re-manufacturers would like to start placing their CE marked SUDs on the UK market. Re-manufacturing of class I devices is, however, excluded from the scope of the Guidance as these devices are subject to self-assessment prior to CE marking.

Pursuant to the Guidance, the re-manufacturer assumes full legal responsibility and liability for the re-manufactured device. Moreover, the intended use of the re-manufactured device must be the same as that of the device as originally produced.

The Guidance sets out the requirements that must be respected before a re-manufactured device can be placed on the EU market. These include:

  • Assessment by the re-manufacturer of whether that the SUD is appropriate for re-manufacturing. Clinical and technical testing to establish the maximum number of times the device can be re-manufactured must also be conducted;
  • Assessment by a notified body to confirm both, the validity and surety of all manufacturing processes and, compliance with the safety and performance provisions of the Medical Devices Directive (Directive 95/42 EEC);
  • The device should be cleaned, disinfected and sterilized through tested and validated processes that are periodically audited;
  • The re-manufactured device should bear a new CE mark;
  • The packaging or device should carry the single-use symbol; and
  • The packaging and instructions should clearly state that the SUD is re-manufactured and should identify the re-manufacturer.

The post-market surveillance responsibilities of the re-manufacturer include:

  • Recording the number of times the device has been re-manufactured and to whom it was supplied;
  • Reporting adverse events in accordance with applicable procedures and time limits;
  • Monitoring problems associated with the original device to determine if these are relevant to the re-manufacturer device; and
  • Managing product safety notification procedures or recall actions in relation to re-manufactured products.

The Guidance provides that re-manufactured devices should be supplied to healthcare institutions through closed loop contracts. Devices should be used only once, on an individual patient during a single procedure. The devices should then be returned to the original re-manufacturer in containers provided by them. Re-manufactured devices should not be resold to third parties or reprocessed. The healthcare facility is responsible for returning the devices to the original re-manufacturer, destroying or returning devices that have been re-manufactured the maximum number of times specified and reporting any issues with the device to the re-manufacturer.

The guidance distinguishes between re-manufactured SUDs and devices that are reprocessed or fully refurbished, which are limited to multi-use devices and for which separate guidance applies.

For further information visit https://www.gov.uk/government/publications/single-use-medical-devices.

 

Photo of Elisabethann Wright Elisabethann Wright
Read more about Elisabethann WrightEmail
  • Posted in:
    Health Care and Life Sciences
  • Blog:
    Focus on Regulation
  • Organization:
    Hogan Lovells
  • Article: View Original Source

Call us at 1-800-913-0988 or email sales@lexblog.com.

Facebook LinkedIn Twitter RSS
  • About LexBlog
  • The Field We Built
  • Our Beliefs
  • Our Team
  • Contact LexBlog
  • Disclaimer
  • Editorial Policy
  • Terms of Service
  • Get Started
  • Publishing Solutions
  • Compass
  • Submit a Request
  • Support Center
  • System Status
Copyright © 2026, LexBlog, Inc. All Rights Reserved.
Law blog design & platform by LexBlog LexBlog Logo